What minimum functions as per FSS code are required to be performed by Inert Gas Systems?

Table of Contents

Minimum functions required by FSS Code

The system shall be capable of:

1) inerting empty cargo tanks by reducing the oxygen content of the atmosphere in each tank to a level at which combustion cannot be supported

2) maintaining the atmosphere in any part of any cargo tank with an oxygen content not exceeding 8% by volume and at a positive pressure at all times in port and at sea except when it is necessary for such a tank to be gas-free

3) eliminating the need for air to enter a tank during normal operations except when it is necessary for such a tank to be gas-free

4) purging empty cargo tanks of a hydrocarbon gas, so that subsequent gas-freeing operations will at no time create a flammable atmosphere within the tank.